Part Number Hot Search : 
FAN1950 AK4556V AN7710SP SDS152KF ZDT1053 ECCM1 74HCU04 4148SE
Product Description
Full Text Search
 

To Download CCP-33S6E-D Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ? 2013 teledyne relays (800) 284-7007 ? www.teledynecoax.com ccp-33s page 1 ccp-33s\072013\q3 series ccp-33s low pim, miniature dc?3 ghz latching spdt coaxial switch coax switches environmental and physical characteristics operating temperature ?40c to 65c vibration (mil-std-202 method 214, condition d, non-operating) 10 g?s rms shock (mil-std-202 method 213, condition d, non-operating) 500 g?s standard actuator life 1,000,000 cycles connector type sma humidity (moisture seal) available weight 1.65 oz. (46.78g) (max.) performance characteristics frequency dc?3 ghz insertion loss, db, max. 0.2 isolation, db, min. 90 vswr , max. 1.25:1 rf power (cw), w, max 75w @3ghz part numbering system connector s: sma female actuator voltage 6: 28 vdc latching 7: 15 vdc latching 8: 12 vdc latching 9: 24 vdc latching actuator type 0: standard contacts c: indicator contacts d: self cutoff only e: indicators and self cutoff **see parts list on pages 6 options t: ttl drivers with diodes d: transient suppression diodes r: positive + common n: narrow body m: moisture seal s: 9 pin d-sub connector actuator voltage ccp-33 s 6 c - t ** series connectors actuator type options for additional options, contact factory. part number description ccp-33s commercial latching spdt, dc-3 ghz these switches are classi ed to have extremely low passive intermodulation for use in narrow bandwidth communications applications. the ccp-33s is a broadband, spdt, electromechanical, coaxial switch designed to switch a microwave signal from a common input to either of two outputs. the characteristic impedance is 50 ohms. the small switches incorporate sma connectors. the ccp-33s series switch is offered with a latching actuator. this design is compatible with the two most common mounting hole patterns. the ccp-33s series switch is interchangeable with a variety of switches. electrical characteristics form factor spdt, break before make frequency range dc?3 ghz characteristic impedance 50 ohms switching time 10 ms (max.) actuation voltage available 12 15 24 28 v actuation current, max. @ ambient 140 170 90 65 ma passive intermodulation characteristics tone 1 frequency (mhz) tone 2 frequency (mhz) im3 frequency (mhz) pim threshold (dbc) 1945 1990 1900 -140.0 p1 p2 (dbm) pim (dbc) peak pim (dbc) 43 -143.1 -142.2
ccp-33s page 2 specifications are subject to change without notice ? 2013 teledyne coax switches ccp-33s\072013\q3 series ccp-33s low pim, miniature dc?3 ghz latching spdt coaxial switch coax switches schematics and mechanical outline 9 pin d-sub pinout for latching spdt options pin no. basic indicators ttl indicators & ttl 11 1 22 2 3 c c common common 411 522 6vswvsw 7a a 8b b 9c c truth table (with ttl option) logic input rf path indicator (if applicable) 12 in to 1 in to 2 ab 00 no change 10 on off c 0 01 off on 0 c 11 forbidden p/n: voltage: vdc d/c: m/o: rohs made in teledyne coax switches j1 j2 jc
? 2013 teledyne relays (800) 284-7007 ? www.teledynecoax.com ccp-33s page 3 ccp-33s\072013\q3 series ccp-33s low pim, miniature dc?3 ghz latching spdt coaxial switch coax switches typical broadband rf performance curves rf notes -1.00 -0.90 -0.80 -0.70 -0.60 -0.50 -0.40 -0.30 -0.20 -0.10 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 insertion loss (db) frequency (ghz) insertion loss (dc-3 ghz) 1.00 1.05 1.10 1.15 1.20 1.25 0.00 0.50 1.00 1.50 2.00 2.50 3.00 frequency (ghz) vswr (dc-33 ghz) insertion (db) -140.00 -120.00 -100.00 -80.00 -60.00 -40.00 -20.00 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 isolation (db) frequency (ghz) isolation (dc-3 ghz)
ccp-33s page 4 specifications are subject to change without notice ? 2013 teledyne coax switches ccp-33s\072013\q3 series ccp-33s low pim, miniature dc?3 ghz latching spdt coaxial switch coax switches power handling vs. frequency estimates based on the following reference conditions: ? ambient temperature of 40c or less ? sea level operation ? load vswr of 1.20:1 maximum ? no high-power (hot) switching please contact teledyne coax switches for derating factors when applications do not meet the foregoing reference conditions. typical power performance curve 3000 power (w) frequency ghz 2000 1000 800 600 400 300 200 100 80 60 40 30 20 10 .1 .2 .3 .4 .6 .8 1 2 standard sma switches 3
? 2013 teledyne relays (800) 284-7007 ? www.teledynecoax.com ccp-33s page 5 ccp-33s\072013\q3 series ccp-33s low pim, miniature dc?3 ghz latching spdt coaxial switch coax switches actuator an actuator is the electromechanical mechanism that transfers the rf contacts from one position to another upon dc command. arc suppression diode a diode is connected in parallel with the coil. this diode limits the ?reverse emf spike? generated when the coil de- energizes to 0.7 volts. the diode cathode is connected to the positive side of the coil and the anode is connected to the negative side. date code all switches are marked with either a unique serial number or a date code. date codes are in accordance with mil- std-1285 paragraph 5.2.5 and consist of four digits. the rst two digits de ne the year and the last two digits de ne the week of the year (yyww). thus, 1032 identi es switches that passed through nal inspection during the 32nd week of 2010. latching a latching switch remains in the selected position whether or not voltage is maintained. this can be accomplished with either a magnetic or mechanical latching mechanism. indicator indicators tell the system which position the switch is in. other names for indicators are telemetry contacts or tellback circuit. indicators are usually a set of internally mounted dc contacts linked to the actuator. they can be wired to digital input lines, status lights, or interlocks. unless otherwise speci ed, the maximum indicator contact rating is 30 vdc, 50 ma, or 1.5 watts into a resistive load. isolation isolation is the measure of the power level at the output connector of an unconnected rf channel as referenced to the power at the input connector. it is speci ed in db below the input power level. self-cutoff the self-cutoff option disables the actuator current on completion of actuation. either a series contact (linked to the actuator) or an ic driver circuit provides the current cutoff. this option results in minimum power consumption by the rf switch. cutthroat is another name used in the industry for this option. pulse latching is a term used to describe a switch without this feature. spdt switch a single-pole double-throw, bi-directional switch that can be used as having one input and two outputs or two inputs and one output. switching time switching time is the total interval beginning with the arrival of the leading edge of the command pulse at the switch dc input and ending with the completion of the switch transfer, including contact bounce. it consists of three parts: (1) inductive delay in the coil, (2) transfer time of the physical movement of the contacts, and (3) the bounce time of the rf contacts. ttl switch driver option as a special option, switch drivers can be provided for both failsafe and latching switches, which are compatible with industry-standard low-power schottky ttl circuits. performance parameters vs frequency generally speaking, the rf performance of coaxial switches is frequency dependent. with increasing frequency, vswr and insertion loss increase while isolation decreases. all data sheets specify these three parameters as ?worst case? at the highest operating frequency. if the switch is to be used over a narrow frequency band, better performance can be achieved. actuator current vs temperature the resistance of the actuator coil varies as a function of temperature. there is an inverse relationship between the operating temperature of the switch and the actuator drive current. for switches operating at 28 vdc, the approximate actuator drive current at temperature, t, can be calculated using the equation: magnetic sensitivity an electro-mechanical switch can be sensitive to ferrous materials and external magnetic elds. neighboring ferrous materials should be permitted no closer than 0.5 inches and adjacent external magnetic elds should be limited to a ux density of less than 5 gauss. glossary i a [1 + .00385 (t-20)] where: i t = actuator current at temperature, t i a = room temperature actuator current C see data sheet t = temperature of interest in c i t =
ccp-33s page 6 specifications are subject to change without notice ? 2013 teledyne coax switches ccp-33s\072013\q3 series ccp-33s low pim, miniature dc?3 ghz latching spdt coaxial switch coax switches latching ccp-33s number list * x = 6 (28vdc), 7 (15vdc), 8 (12vdc) and 9 (24vdc) p art n o .p art n o .p art n o . 1 ccp-33sxc 43 ccp-33sxd-n 85 ccp-33sxe-tnm 2 ccp-33sxc-d 44 ccp-33sxd-n 86 ccp-33sxe-tnms 3 ccp-33sxc-dm 45 ccp-33sxd-nm 87 ccp-33sxe-tns 4 ccp-33sxc-dms 46 ccp-33sxd-nms 88 ccp-33sx0 5 ccp-33sxc-dn 47 ccp-33sxd-ns 89 ccp-33sx0-d 6 ccp-33sxc-dnm 48 ccp-33sxd-r 90 ccp-33sx0-dm 7 ccp-33sxc-dnms 49 ccp-33sxd-rm 91 ccp-33sx0-dms 8 ccp-33sxc-dns 50 ccp-33sxd-rms 92 ccp-33sx0-dn 9 ccp-33sxc-dr 51 ccp-33sxd-rn 93 ccp-33sx0-dnm 10 ccp-33sxc-drm 52 ccp-33sxd-rnm 94 ccp-33sx0-dnms 11 ccp-33sxc-drms 53 ccp-33sxd-rnms 95 ccp-33sx0-dns 12 ccp-33sxc-drn 54 ccp-33sxd-rns 96 ccp-33sx0-dr 13 ccp-33sxc-drnms 55 ccp-33sxd-rs 97 ccp-33sx0-drm 14 ccp-33sxc-drns 56 ccp-33sxd-s 98 ccp-33sx0-drms 15 ccp-33sxc-drs 57 ccp-33sxd-t 99 ccp-33sx0-drn 16 ccp-33sxc-ds 58 ccp-33sxd-tm 100 ccp-33sx0-drnms 17 ccp-33sxc-m 59 ccp-33sxd-tms 101 ccp-33sx0-drns 18 ccp-33sxc-ms 60 ccp-33sxd-tn 102 ccp-33sx0-drs 19 ccp-33sxc-n 61 ccp-33sxd-tnm 103 ccp-33sx0-ds 20 ccp-33sxc-nm 62 ccp-33sxd-tnms 104 ccp-33sx0-m 21 ccp-33sxc-nms 63 ccp-33sxd-tns 105 ccp-33sx0-ms 22 ccp-33sxc-ns 64 ccp-33sxe 106 ccp-33sx0-n 23 ccp-33sxc-r 65 ccp-33sxe-m 107 ccp-33sx0-nm 24 ccp-33sxc-rm 66 ccp-33sxe-ms 108 ccp-33sx0-nms 25 ccp-33sxc-rms 67 ccp-33sxe-n 109 ccp-33sx0-ns 26 ccp-33sxc-rn 68 ccp-33sxe-n 110 ccp-33sx0-r 27 ccp-33sxc-rnm 69 ccp-33sxe-nm 111 ccp-33sx0-rm 28 ccp-33sxc-rnms 70 ccp-33sxe-nms 112 ccp-33sx0-rms 29 ccp-33sxc-rns 71 ccp-33sxe-ns 113 ccp-33sx0-rn 30 ccp-33sxc-rs 72 ccp-33sxe-r 114 ccp-33sx0-rnm 31 ccp-33sxc-s 73 ccp-33sxe-rm 115 ccp-33sx0-rnms 32 ccp-33sxc-t 74 ccp-33sxe-rms 116 ccp-33sx0-rns 33 ccp-33sxc-tm 75 ccp-33sxe-rn 117 ccp-33sx0-rs 34 ccp-33sxc-tms 76 ccp-33sxe-rnm 118 ccp-33sx0-s 35 ccp-33sxc-tn 77 ccp-33sxe-rnms 119 ccp-33sx0-t 36 ccp-33sxc-tnm 78 ccp-33sxe-rns 120 ccp-33sx0-tm 37 ccp-33sxc-tnms 79 ccp-33sxe-rs 121 ccp-33sx0-tms 38 ccp-33sxc-tns 80 ccp-33sxe-s 122 ccp-33sx0-tn 39 ccp-33sxc-ts 81 ccp-33sxe-t 123 ccp-33sx0-tnm 40 ccp-33sxd 82 ccp-33sxe-tm 124 ccp-33sx0-tnms 41 ccp-33sxd-m 83 ccp-33sxe-tms 125 ccp-33sx0-tns 42 ccp-33sxd-ms 84 ccp-33sxe-tn 126 ccp-33sx0-ts


▲Up To Search▲   

 
Price & Availability of CCP-33S6E-D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X